The following is an example of the topics taught for RTFI. All course outlines can be, and usually are, modified to meet client needs.
|
|
Review Of The Radiographic Variables Related To Film Interpretation
|
-
Radiation
-
Energy-vs.-wavelength
-
Intensity
-
Sources (x-ray/gamma-ray)
-
Source to Film Distance
-
Film to Object Distance
-
Source/Target Size
-
Alignment
-
Material
-
Thickness
-
Type (Density)
-
Configuration
-
Process (Castings, Forgings, Welds, etc.)
|
|
Film
|
-
Speed
-
Graininess
-
Handling
-
Screens
-
Density
-
Exposure/Time
-
Fog
-
Density Equation
|
|
Radiographic Viewing
|
-
Film Illuminator requirements
-
High Intensity Illuminator
-
Background Lighting
-
Multiple/composite viewing
-
Penetrameter Placement
-
Film Id
-
Location markers
-
Dark adaptation/visual acuity
-
Densitometer Operation Calibration Maintenance
-
Density Measurements
|
|
Radiographic Image Quality
|
|
|
Exposure Techniques
|
-
Multiple Film
-
Coverage
-
Superimpose
-
Single Wall Exposure - Single Wall View
-
Double Wall Exposure - Single Wall View
-
Double Wall Exposure - Double Wall View
-
Panoramic
|
|
Discontinuities
|
-
Weld
-
Aircraft Assemblies
-
Composites
-
Miscellaneous Products
|
|
Radiographic Artifacts
|
-
Prior to Processing Scratches Crimp Marks Pressure Marks Static Marks Fog Screen Defects Light Leaks Finger Marks
-
During Processing Chemical Spots Dirt Pi Lines Pressure Marks Overlap
-
After Processing Scratches Dirt Creases
-
Other
|
|
Codes, Procedures, and Written Practices
|
-
Military Standards (MIL-STD 453, 271, etc.)
-
ASME Section V
-
API 1104
-
AWS D1.1
-
ASTM E94
-
ASTM E142
-
Other
-
Procedures and Written Practices
|
|
Radiographic Report Forms
|
-
Purposes of Report Forms
-
Requirements
|
|